Key words:model; modulus of rupture; Osadebe’s theory; optimisation; mix proportions.
[2] International Concrete Repair Institute Concrete Repair Terminology [online]. Available from: http://www.google.com/search.
[3] Hueste, M.B.D.; Chompreda, P.; Trejo David; Clinic Daren B.H.; and Feating, P.B.( 2004). Mechanical properties of high strength concrete for prestressed members. ACI Structural Journal.
[4] Kohler, E.; Ali, A.; and Harvey, J. ( 2005). Flexural fatigue life of hydraulic cement concrete beam. Department of Transportation, Partnered Pavement Research Centre, University of Carlifornia, Davies and Berkeley.
[5] Elinwa, A.U.; and Ejeh, S.P. (2005). Characteristics of sisal fibre reinforced concrete. Journal of Civil Engineering Research and Practice, 2 (1), 1-14.
[6] British Standards Institution, 1978. BS 12: 1978. Specification for Portland cement.
[7] British Standards Institution (1992). BS 882: 1992. Specification for aggregates from natural sources for concrete.
[8] British Standards Institution (2002). BS EN 1008: 2002. Mixing water for concrete -Specification for sampling, testing and assessing the suitability of water, including water recovered from processes in the concrete industry, as mixing water for concrete.
[9] Scheffe, H. (1958). Experiments with Mixtures. Royal Statistical Society Journal, 20 (B). 344-360.
[10] Osadebe, N.N. (2003). Generalised mathematical modeling of compressive strength of normal concrete as a multi-variant function of the properties of its constituent components. A paper delivered at the college of Engineering, University of Nigeria, Nsukka.
[11] Okere, C.E. (2006). Mathematical Models for Optimisation of Modulus of Rupture of Concrete. Thesis (M. Eng). Federal University of Technology Owerri.
Keywords –Business-IT Alignment (BITA); IT Governance; Information Technology Infrastructure Library (ITIL); Luftman’s maturity model.
[2] M. McGee, "InformationWeek," no. http://www.informationweek.com/news/210300331, 2008.
[3] J. Luftman, "Assessing IT/business alignment," Information Strategy 20 , p. 7, 2003.
[4] J. McKeen and H. Smith, "Making IT Happen: Critical Issues in IT Management.," no. John Wiley & Sons, 2003.
[5] OGC, "Introduction to ITIL, The IT Service Management Forum,, .pdf , UK," 2007.
[6] A. J. G. Silvius, "The Impact of National Cultures on Business & IT Alignment," Communications of the IIAM, 2008.
[7] R. S. Tapia, "Developing a Maturity Model for IT Alignment in a Cross-Organizational Environment," 2nd Dutch/Belgian Conference on Enterprise Information Systems (EIS), 2007.
[8] H. M. Chen, "Towards Service Engineering: Service Orientation and Business-IT Alignment," in 41st Hawaii International Conference on System Sciences (HICSS), 2008.
[9] 1. c. a. V. N. Henderson, "Strategic Alignment:Leveraging Information Technology for Transforming Organizations," vol. 32, 1993.
[10] J. Luftman, "Assessing Business-IT Alignment Maturity," Communications of the Association for Information Systems, vol. 4, p. 14, 2000.
Keywords –Domestic refrigerator, HFC134a, POE oil, SUNISO 3GS mineral oil, Water-cooled condenser
[1] S.S. Hu, B.J. Huang, “Study of a high efficiency residential split water-cooled air conditioner”, Applied Thermal Engineering 25 (2005) 1599–1613.
[2] H.I. Abu-Mulaweh, “Design and performance of a thermosiphon heat recovery system”, Applied Thermal Engineering 26 (2006) 471–477.
[3] Douglas T.Reindl, Todd B. Jekel, “Heat Recovery In Industrial Refrigeration”, ASHRAE Journal, August 2007.
[4] M. M. Rahman, Chin Wai Meng, Adrian Ng, “Air Conditioning and Water Heating- An Environmental Friendly and Cost Effective Way of Waste Heat Recovery”, AEESEAP, Journal of Engineering Education 2007, Vol. 31, No. 2
[5] Sheng-shan Bi, Lin Shi , Li-li Zhang, “Application of nanoparticles in domestic refrigerators”, Applied Thermal Engineering 28 (2008) 1834–1843.
[6] Romdhane Ben Slama, “Water-heater coupled with the refrigerator to develop the heat of the condenser”, International Renewable Energy Congress November 5-7, 2009 - Sousse Tunisia.
Keywords –Darlington pair, solar radiation, comparator circuit, orthogonal position
[1] Bailis, Robert. “Wood in Household Energy Use”.Encyclopedia of Energy.2004. Pages 516, & 518.
[2] Ackermann, T., Andersson, G., Söder, L. “Distributed generation: a definition”. Electric Power Systems Research. April 2000. Page 195.
[3] Banerjee, “Comparison of Options for Distributed Generation in India”. Energy Policy.Pages 105-110.
[4] Goetzberger, A., Hebling, C., Schock, H..“Photovoltaic materials, history, status and outlook”.Materials Science and Engineering: R: Reports. 2002.
[5] Mousazadeh, H., Keyhani, A., Javadi, A., Mobli, H., Abrinia, K., Sharifi, A..“A review of principle and sun-tracking methods for maximizing solar systems output”.Renewable and Sustainable Energy Reviews. January 2009. Pages 1800, 1800, 1804, 1806, & 1812.
[6] Krauter, Stefan. “Solar Electrical Power Generation: Photovoltaic Energy Systems”. Springer. 2006. Pages 21-22.
[7] Mehleri, E., Zervas, P., Sarimveis, H., Palyvos, J., Markatos, N..“Determination of the optimal tilt angle and orientation for solar photovoltaic arrays”.Renewable Energy. April 2010. Page 2469.
[8] J. Richard Williams, (1977) revised edition, solar energy technology and application. Publisher: annabor science publishers INC
[9] Roy Meador, (1978) first edition, future energy alternatives. Publisher: annabor science publishers INC.
[10] Milton a Rothman, (1977) first edition, energy and the future. Publisher: franklin watts INC in USA.
[11] I.M. Blair and B.D. Jones, (1976) first edition, aspects of energy conversion. Publisher: pergamon press ltd
[12] http://www.solar expect. Com/PV types.htm/ „‟solar energy and its relevance‟‟ Oct 8, 2011.
[1]. S.K.Khaden, M.Basu ,M.F.Conlon ," Power quality in grid connected renewable energy systems: Role of custom power devices". ICERPQ, Granda,spain, Mar-2010.
[2]. Dr.Jazeri, Dr.B.Mozafari," A Novel DG grid interface control strategy for active power injection management and power quality improvement" IPSC,Tahran,Iron, Nov-2011.
[3]. A.Arulampalam, M.Barnes, A.Engler, " Control of power electronics iinterfaces in distributed generation micro grids" IJE,vol.5,2004.,page no.1-21.
[4]. IonelVECHIU, GeluGURGUIATU, Emil ROSU,"Advanced Active Power Conditioner to Improve Power Quality in Microgrids" IPEC.,IEEE Conf.,2010.
[5]. F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, “Overview of control and grid synchronization for distributed power generation systems,” IEEE Trans. Ind. Electron., vol. 53, no. 5, pp 1398–1409, Oct. 2006.
[6]. J. M. Carrasco, L. G. Franquelo, J. T. Bialasiewicz, E. Galván, R. C.P. Guisado, M. Á. M. Prats, J. I. León, and N. M. Alfonso, Power- electronic systems for the grid integration of renewable energy sources: A survey,” IEEE Trans. Ind. Electron., vol. 53, no. 4, pp.1002–1016, Aug. 2006.
[7]. B. Renders, K. De Gusseme, W. R. Ryckaert, K. Stockman, L. Van- develde, and M. H. J. Bollen, “Distributed generation for mitigating voltage dips in low-voltage distribution grids,” IEEE Trans. Power. Del., vol. 23, no. 3, pp. 1581–1588, Jul. 2008.
[8]. M.Singh, V.Khadkkikar, A.Chandra, Rajiv K.Varma,” Grid interconnection of renewable energy sources at distribution level with power quality improvement” vol.26., no.1., jan-2011.
[9] Rachid Dehini, Brahim Ferdi "STATCOM Dc-bus Voltage ControllerBased on Fuzzy logic" IJAEST vol.11.,pp.281-285.
[10] M.Bhanu Siva, M.R.P Reddy, Ch.Rambabu "Power Quality Improvement of Three-phase four-wire DSTATCOM with Fuzzy logic Controller" ICSIT.,vol.2,pp. 2273-2273.,2011.
[11] M . Nejad, S. Pierfederici, J.P. Martin, F. Meibody-Tabar, ―Study of an hybrid current controller suitable for DC–DC or DC–AC applications,‖ IEEE Transactions on Power Electronics, vol. 22, pp 2176–2186. November 2007.
[12] Copper Development Association, ―Voltage Disturbances. Standar EN50160 Voltage Characteristics in Public Distribution Systems,2004.